Loading...

Reloadable Linear Cutter Staplers

Linear Cutter Staplers places two double staggered rows of titanium staples and simultaneously cuts and div ides tissue between the two double rows. Reloadable staple cartridges allows to use one device for multiple firings per patient. Available versions: with cutting knife integrated into the staple cartridge, with cutting knife integrated into the device body

Order information
Reloadable Linear Cutter Staplers

Product description

  • Linear Cutter Staplers are used in the abdominal, gynecological, pediatric and thoracic surgeries for resection, transection of tissues, or creation of anastomosis. Stapler places two double staggered rows of titanium staples, cuts and divides tissue between the two double rows simultaneously.
  • Staplers consists of two parts – resistant shear and jaw with reload, built-in.
  • Bringing in/out of the two halves of the apparatus is carried out with the help of a locking lever. Stitching is performed by simultaneous dissection of the tissue using a special slider.
  • Staples in reload are staggered for even pressure distribution on the tissue after stitching and for tightness of staples connection.
  • Material of staples is suitable for MRI-procedures
  • Linear Cutter Staplers are supplied with a color coded reload. Color coding depends on tissue thickness. It is possible to replace the reload during one operation up to 7 times and make 8 sutures with it.
  • The reload is replaceable for single patient use.

Version with cutting knife integrated into the staple cartridge

  • Available in 60mm and 80mm staple lengths with reload units available for both standard tissue (3.8mm) and thick tissue (4.5mm).
  • Every staple cartridge comes with a retaining pin that ensures correct cut and suture length.
  • Ergonomic ridged handle for extra control.
  • Length indicator on both sides of cartridge fork.
  • Cam gear design ensures consistent staple formation.
  • True intermediate locking position with large jaws opening allows for single handed positioning of linear cutter.
  • Unique firing safety to prevent inadvertent pre-firing duringpreparation and positioning.
  • Empty cartridge lockout to prevent firing of empty/used cartridges.
Order information
Linar cutter stapler with cutting knife integrated into the staple cartridge

Version with cutting knife integrated into the device body

  • Available in 60, 80 and 100 mm staple lengths with reload units available for both standard tissue (3.8mm) and thick tissue (4.5mm).
  • Intermediate locking position lets surgeons position and inspect the tissue before closing. Each device may be reloaded up to 7 times for a maximum of 8 firings per patient.
  • Ergonomic handle with rubber grips for extra control.
  • New blade with each cartridge guarantees smooth, precise transection with each firing, reducing the risk of cross infection.
  • Automatic safety lock-out mechanism incorporated within each cartridge.
  • Rear hinge allows for one handed operation.
  • Adjustable firing lever enables you to fire from either side of the device.
  • Automatic safety lock-out mechanism incorporated within each cartridge.
  • Quick release button enabling single handed operation.
Order information
Linar cutter stapler with cutting knife integrated into the device body
Simultaneously cuts and divides tissue between the two double rows

Linear Cutter Stapler Uses

The Single Use Linear Cutter can be used in the abdominal, gynecological, pediatric and thoracic surgeries for resection, transection of tissues, or creation of anastomosis. Stapler places two double staggered rows of titanium staples, cuts and divides tissue between the two double rows simultaneously.

Longer Staple line than cutting edge, prevents blood leakage

Product gallery

Order information

Linear Cutter Staplers with cutting knife integrated into the staple cartridge

RefSuture length, mmTissue thickness (color code)Open staple height, mmClosed staple height, mm
1847-VLC-B6060Standard3.51.5
1847-VLC-G6060Thickened4.82.0
1847-VLC-B8080Standard3.51.5
1847-VLC-G8080Thickened4.82.0

Linear Cutter Staplers with cutting knife integrated into the device body

RefSuture length, mmTissue thickness (color code)Open staple height, mmClosed staple height, mm
1847-VLC-B60-B60Standard3.51.5
1847-VLC-G60-B60Thickened4.82.0
1847-VLC-B80-B80Standard3.51.5
1847-VLC-G80-B80Thickened4.82.0
1847-VLC-B100-B100Standard3.51.5
1847-VLC-G100-B100Thickened4.82.0

Cartridges without inegrated knife

RefSuture length, mmTissue thickness (color code)Open staple height, mmClosed staple height, mm
1847-VLC60B60Standard3.51.5
1847-VLС60G60Thickened4.82.0
1847-VLС80B80Standard3.51.5
1847-VLС80G80Thickened4.82.0

Cartridges with inegrated knife

RefSuture length, mmTissue thickness (color code)Open staple height, mmClosed staple height, mm
1847-VLSC60B-B60Standard3.51.5
1847-VLSC60G-B60Thickened4.82.0
1847-VLSC80B-B80Standard3.51.5
1847-VLSC80G-B80Thickened4.82.0
1847-VLSC100B-B100Standard3.51.5
1847-VLSC100G-B100Thickened4.82.0

Also recommended products

Reloadable Linear Staplers
Surgical stapling

Reloadable Linear Staplers

Volkmann Reloadable Linear Staplers places two staggered rows of titanium staples, and is available in 30mm, 45mm, 60mm and 90mm staple line lengths with reload units available for both standard tissue (3.8mm) and thick tissue (4.5mm).

Read more
Circular Staplers
Surgical stapling

Circular Staplers

Volkmann Circular staplers are used in general surgery, thoracic surgery, surgical treatment of obesity and in colo-rectal surgery, to perform end-to-end, side-to-end, and side-to-side anastomoses. Volkmann offers 3 types of Circular staplers: straight, curved and curved with longer shaft.

Read more
Endoscopic Linear Cutter Staplers
Surgical stapling

Endoscopic Linear Cutter Staplers

Endoscopic Linear Cutter Staplers are used in open and endoscopic surgeries formechanical sutures, incisions and anastomoses, suitable for working with articulating and straight reload units with equal or different levels of staples. Staplers are supplied in 3 different reload units versions depending on suture length of 30, 45, 60 mm that suitable for tissues of various thicknesses: from vascular to super thick.

Read more
Circular Staplers for Rectal Prolapse and Haemorrhoids
Surgical stapling

Circular Staplers for Rectal Prolapse and Haemorrhoids

Volkmann Circular staplers are used in general surgery, thoracic surgery, surgical treatment of obesity and in colo-rectal surgery, to perform end-to-end, side-to-end, and side-to-side anastomoses. Volkmann offers 3 types of Circular staplers: straight, curved and curved with longer shaft.

Read more